Autocalibración

Referencia técnica sobre Autocalibración para el diseño, integración e implementación de sistemas de energía inalámbrica.

6 minArtículo 13/14Control de Potencia con IA
Self Calibration — educational diagram
Fig.: Diagrama educativo de “Self Calibration”.

Self-calibration lets a wireless dock learn its normal electrical personality after installation or component replacement. Manual calibration with external LCR meters does not scale when hundreds of pads roll out across a warehouse network.

SiCore self-calibration runs scripted low-power sequences: empty pad baseline, known test load or mated reference receiver, and optional fleet-provided golden vehicle — storing results in non-volatile memory with temperature tags.

01What gets calibrated

  • FOD empty-pad and mated-receiver reference signatures.
  • Power meter alignment between primary sensing and secondary reported power.
  • Frequency search seeds for local ferrite batch and coil serial.
  • Communication latency and handshake timeouts for the site's network load.
Self Calibration — supporting diagram
Fig.: Ilustración de apoyo para “Self Calibration”.

02When recalibration runs

Triggers include first power-on, firmware update affecting control gains, replaced capacitor bank or coil assembly, and scheduled drift checks after N cycles or thermal seasons. Forced recalibration after maintenance prevents a swapped receiver board from skewing FOD baselines.

03Commissioning workflow

Installers confirm mechanical pad placement, run the guided calibration wizard, and verify a full-power test charge with sign-off captured in the fleet portal. Self-calibration reduces field dependency on expert field application engineers — but it does not replace correct mechanical install.